Hitta dina Produkter
Hitta dina Leverantörer
Hitta dina Branscher
Hitta dina Hållbara lösningar
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Density | DIN EN ISO 1183-1 | g / cm3 | >0,93 | 
| Water absorption | DIN EN ISO 62 | % | <0,01 | 
| Flammability (Thickness 3 mm / 6 mm) | UL 94 | HB | |
| Molecular weight-106 g/mol~ 9 | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Elongation at break | DIN EN ISO 527 | % | >50 | 
| Tensile modulus of elasticity | DIN EN ISO 527 | MPa | >650 | 
| Notched impact strength | DIN EN ISO 11542-2 | kJ / m2 | >100 | 
| Shore hardness | DIN EN ISO 868 | scale D | >63 | 
| Wear resistance | Sand-slurry | 80 | |
| Sand Slurry | 1018 Steel=10 | ~ 80 | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Melting temperature | ISO 11357-3 | °C | 130 ... 135 | 
| Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,40 | 
| Thermal capacity | DIN 52612 | kJ / (kg * K) | 1,90 | 
| Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 150 ... 230 | 
| Service temperature, long term | Average | °C | -250 … 80 | 
| Service temperature, short term (max.) | Average | °C | 130 | 
| Vicat softening temperature | DIN EN ISO 306, Vicat B | °C | 79 |